Share  
Print  
LITTELFUSE

Littelfuse Fuse: 1/2 A, 250V AC, 2 in L x 9/16 in dia Fuse Size, Cylindrical Body, FLNR

Hover over image to magnify
Fuse,Class RK5,1/2A,Flnr
Fuse,Class RK5,1/2A,Flnr
Double tap image to magnify
Fuse,Class RK5,1/2A,Flnr
Fuse,Class RK5,1/2A,Flnr

#941499-7Pkg Qty: 1

$13.89 pkg | $13.89 ea

In Stock

Shipping to 43085
Expected to arrive Tue. Mar 25.
|

Technical Specifications

Key Specifications
AC Voltage Rating
250 VAC
Indicating / Nonindicating
Nonindicating
Body Material
Fiberglass
Interrupt Rating
200kA at 250 VAC, 20kA at 125 VDC
Body Style
Cylindrical
Item
Fuse
Brand
LITTELFUSE
Length
2 in.
Class
RK5
Mfr. Part Number
FLNR.500
DC Voltage Rating
125 VDC
Package Quantity
1
Diameter
9/16 in.
Rejection / Nonrejection
Rejection
Element
Dual
Series
FLNR
Functionally Equal To
Bussmann FRN-R, Edison ECNR, Littelfuse FLNR, Mersen TR-R
Shipping Weight
.03 lb.
Fuse Amps
1/2 A
Speed
Time Delay
General
AC Voltage Rating
250V AC
Fits Fuse Block Style
Rejection
Compatible Fuse Block Series
LFR
Fuse Size
2 in L x 9/16 in dia
DC Voltage Rating
125V DC
Interrupt Rating
200kA at 250V AC, 20kA at 125V DC
Element
Dual
Speed
Time Delay
Equivalent Brand and Series
Bussmann FRN-R, Edison ECNR, Littelfuse FLNR, Mersen TR-R
Standards
CE, CSA Certification, QPL-W-F-1814, UL 248-12 Class RK5
Equivalent Series
ECNR, FLNR, FRN-R, TR-R

Product Description

These 250VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK5 fuses provide moderate current limitation for general use applications where more current-limiting RK1 fuses aren't needed. These fuses have an interrupting rating (IR) of 200kA and are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Compliance & Restrictions

California Proposition 65 Icon
WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Item Barcode

9414997
Fuse,Class RK5,1/2A,Flnr

For more product information by email, click here