Share  
Print  
BUSSMANN

Bussmann Fuse: 150 A, 250V AC, 7-1/8 in L x 1-9/16 in dia Fuse Size, Blade Body

Hover over image to magnify
Fuse,Class RK1,150A,Lpn-Rk-Sp
Fuse,Class RK1,150A,Lpn-Rk-Sp

#941317-2 | Pkg Qty: 1

$217.24 pkg | $217.24 ea

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
Amperage
150 A
Item
Fuse
Body Material
Melamine
Mfr. Part Number
LPN-RK-150SP
Body Style
Blade
Package Quantity
1
Brand
BUSSMANN
Series
LPN-RK-SP
Class
RK1
Shipping Weight
.85 lb.
Diameter
1 9/16 in.
Voltage Rating
250VAC/DC
General
AC Voltage Rating
250V AC
Fits Fuse Block Style
Rejection
Amps
150 A
Fuse Size
7-1/8 in L x 1-9/16 in dia
Compatible Fuse Block Series
HM600, R250
Interrupt Rating
100kA at 250V DC, 300kA at 250V AC
DC Voltage Rating
250V DC
Length
7 1/8 in
Element
Dual
Speed
Time Delay
Equivalent Brand and Series
Bussmann LPN-RK-SP, Littelfuse LLNRK, Mersen A2D-R
Standards
CE, UL Special Purpose Guide JFHR, Guide JDDZ, File E4273, CSA Class 1422-02, File 53787, CSA C22.2, No. 248.12
Equivalent Series
A2D-R, LLNRK, LPN-RK-SP
Visual Indication
Nonindicating

Product Description

Time-delay, nonindicating UL Class RK1 fuses tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK1 fuses, they open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK1 fuses are more current-limiting than RK5 fuses to react more quickly to overcurrent. These fuses are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. These fuses are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Item Barcode
9413172
Fuse,Class RK1,150A,Lpn-Rk-Sp
 NameItemDescription
Grainger DropshipGrainger Dropship4XF63
UNSPSC CODESUNSPSC CODES39121604
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009