Share  
Print  
BUSSMANN

Bussmann FRN-R Series, 175A Fuse; 7-1/8 in. L x 1-9/16 in. dia.

Hover over image to magnify
Fuse,Class RK5,175A,Frn-R
Fuse,Class RK5,175A,Frn-R

#939053-8 | Pkg Qty: 1

$140.35 pkg | $140.35 ea
Fuse Amps : 175A

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
250 VAC
Indicating / Nonindicating
Nonindicating
Body Material
Fiberglass
Interrupt Rating
200kA at 250 VAC, 20kA at 125 VDC
Body Style
Blade
Item
Fuse
Brand
BUSSMANN
Length
7-1/8 in.
Class
RK5
Mfr. Part Number
FRN-R-175
DC Voltage Rating
125 VDC
Package Quantity
1
Diameter
1-9/16 in.
Rejection / Nonrejection
Rejection
Element
Dual
Series
FRN-R
Functionally Equal To
Littelfuse FLNR, Mersen/Ferraz Shawmut TR-R
Shipping Weight
.75 lb.
Fuse Amps
175A
Speed
Time Delay
General
Compatible Fuse Block Series
HM600, R250
Fuse Size
7-1/8 in L x 1-9/16 in dia
Equivalent Series
ECNR, FLNR, FRN-R, TR-R
Standards
CE, CSA Certification Class 1422-01, UL 248-12 Guide JDDZ

Product Description

These 250VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK5 fuses provide moderate current limitation for general use applications where more current-limiting RK1 fuses aren't needed. These fuses have an interrupting rating (IR) of 200kA and are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Item Barcode
9390538
Fuse,Class RK5,175A,Frn-R
 NameItemDescription
Grainger DropshipGrainger Dropship6F216
UNSPSC CODESUNSPSC CODES39121604
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009

For more product information by email, click here