Share  
Print  
MERSEN

Mersen TRS-R Series, 15A RK5 Fuse; 5 in. L x 13/16 in. dia.

Hover over image to magnify
Fuse,Class RK5,15A,Trs-R Series
Fuse,Class RK5,15A,Trs-R Series

#933559-6 | Pkg Qty: 1

$18.10 pkg | $18.10 ea
Fuse Amps : 15A

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
Indicating / Nonindicating
Nonindicating
Body Material
Polyester
Interrupt Rating
200kA at 600 VAC, 20kA at 300 VDC
Body Style
Cylindrical
Item
Fuse
Brand
MERSEN
Length
5 in.
Class
RK5
Mfr. Part Number
TRS15R
DC Voltage Rating
300 VDC
Package Quantity
1
Diameter
13/16 in.
Rejection / Nonrejection
Rejection
Element
Dual
Series
TRS-R
Functionally Equal To
Bussmann FRS-R, Littelfuse FLSR
Shipping Weight
.13 lb.
Fuse Amps
15A
Speed
Time Delay
General
Compatible Fuse Block Series
2HKRFB, 6HKRFB
Fuse Size
5 in L x 13/16 in dia
Equivalent Series
ECSR, FLSR, FRS-R, TRS-R
Standards
CSA, UL

Product Description

These 600VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK5 fuses provide moderate current limitation for general use applications where more current-limiting RK1 fuses aren't needed. These fuses have an interrupting rating (IR) of 200kA and are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Item Barcode
9335596
Fuse,Class RK5,15A,Trs-R Series
 NameItemDescription
Grainger DropshipGrainger Dropship4YZL3Fuse,Class RK5,15A,TRS-
UNSPSC CODESUNSPSC CODES39121604
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009Fuse,Class RK5,15A,TRS-

For more product information by email, click here