Share  
Print  
EATON BUSSMANN

Eaton Bussmann Fuse: 175 A Amps, 600V AC, H, 9-5/8 in L x 1-13/16 in dia Fuse Size, Blade Body

Hover over image to magnify
Fuse,175A,Class H,Nos,600VAC
Fuse,175A,Class H,Nos,600VAC

#930475-2 | Pkg Qty: 1

$132.32 pkg | $132.32 ea

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
Indicating
No
Amperage
175 A
Indicating / Nonindicating
Nonindicating
Body Material
Melamine
Interrupt Rating
10k A at 600 VAC
Body Style
Blade
Item
Fuse
Brand
EATON BUSSMANN
Length
9-5/8 in.
Class
H
Mfr. Part Number
NOS-175
DC Voltage Rating
Not Rated
Package Quantity
1
Diameter
1-13/16 in.
Rejection / Nonrejection
Nonrejection
Element
Single
Series
Nos
Functionally Equal To
Mersen/Ferraz Shawmut OTS
Shipping Weight
1.25 lb.
Fuse Amps
175A
Speed
Fast Acting
Fuse Holder Code
S
Type
Low Voltage
Fuse Speed
Fast Acting
Voltage Rating
600 VAC
Fuse Voltage Rating
600 VAC
General
Compatible Fuse Block Series
6HKRFB, H600, HM600, HM601, HM602, HM604
Fuse Size
9-5/8 in L x 1-13/16 in dia
Equivalent Series
NLS, NOS, OTS
Standards
CE, Guide JDDZ, File E4273, STD 248-6, CSA Certified Class 1421-01, File 53787
Fits Fuse Block Style
Nonrejection

Product Description

Fast-acting, nonindicating UL Class H and K5 fuses are for general purpose use in existing installations that require a high-sensitivity, fast-blow fuse. These fuses are highly sensitive to changes in current flow and don't tolerate temporary overload currents or power surges, so they open within seconds of being exposed to overloads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. Class H fuses are rated from 65A to 600A with an interrupting rating (IR) of 10kA for low-interrupt applications. Class K5 fuses are rated up to 60A with an interrupting rating (IR) of 50kA for higher interrupt applications and are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent. They're not labeled as current-limiting since they don't have a rejection feature.

UL Class H and K5 fuses are used as replacement fuses for overcurrent protection in older HVAC installations. These fuses are dimensionally the same, so they can be interchanged to change from a current-limiting system using Class K fuses to a noncurrent-limiting system using Class H fuses. Class H fuses are used in low-interrupt applications while Class K fuses have a higher interrupting rating.

Item Barcode
9304752
Fuse,175A,Class H,Nos,600VAC
 NameItemDescription
Grainger DropshipGrainger Dropship1DR13Fuse,175A, Class H,NOS,
UNSPSC CODESUNSPSC CODES39121612
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009Fuse,175A, Class H,NOS,

For more product information by email, click here