Share  
Print  
EATON BUSSMANN

Eaton Bussmann 60A Fast Acting Melamine Fuse with 600VAC Voltage Rating; KTS-R Series

Hover over image to magnify
Fuse,RK1,Kts-R,60A,600VAC,
Fuse,RK1,Kts-R,60A,600VAC,

#924486-6 | Pkg Qty: 1

$107.27 pkg | $107.27 ea

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
Fuse Voltage Rating
600 VAC
Amperage
60 A
Indicating / Nonindicating
Nonindicating
Body Material
Melamine
Interrupt Rating
200kA at 600VAC
Body Style
Cylindrical
Item
Fuse
Brand
EATON BUSSMANN
Length
5-1/2 in.
Class
RK1
Mfr. Part Number
KTS-R-60
DC Voltage Rating
Not Rated
Package Quantity
1
Diameter
13/16 in.
Rejection / Nonrejection
Rejection
Element
Single
Series
Kts-R
Functionally Equal To
Mersen/Ferraz Shawmut A6K-R, Littelfuse KLSR
Shipping Weight
.35 lb.
Fuse Amps
60A
Speed
Fast Acting
Fuse Holder Code
Q
Type
Low Voltage
Fuse Speed
Fast Acting
Voltage Rating
600 VAC
General
Compatible Fuse Block Series
1BR, R600, RM250, RM251, RM252, RM254, RM256, RM600, RM601, RM602, RM604, RM606
Fuse Size
5-1/2 in L x 13/16 in dia
Equivalent Series
A6K-R, KLSR, KTS-R
Standards
CE, UL 248-12 Guide JDDZ, File E4273, CSA C22.2 No. 248.12, Class 1422-02, File 53787
Fits Fuse Block Style
Rejection
Visual Indication
Nonindicating

Product Description

Fast-acting, nonindicating UL Class RK1 fuses open within seconds of being exposed to overloads and short circuits. Also called fast-blow Class RK1 fuses, they are highly sensitive to changes in current flow and don't tolerate temporary overload currents or power surges. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK1 fuses are more current-limiting than RK5 fuses to react more quickly to overcurrent. These fuses are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. These fuses are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Item Barcode
9244866
Fuse,RK1,Kts-R,60A,600VAC,
 NameItemDescription
Grainger DropshipGrainger Dropship1CX15Fuse,RK1,KTS- R,60A,600VAC,
UNSPSC CODESUNSPSC CODES39121625
VMRS (ATA) CODESVMRS (ATA) CODES034-004-009Fuse,RK1,KTS- R,60A,600VAC,

For more product information by email, click here