Technical Specifications

Key Specifications
Agency Compliance
ISO
Maximum Fluid Viscosity
0.14 cP
Amps
4.7
Maximum Head
50 ft.
Bearing Type
Ball
Maximum Liquid Temperature
104°F
Best Efficiency GPM @ Head
8 gpm @ 5 ft.
Maximum Pressure
23 psi
Brand
LIQUIDYNAMICS INC.
Maximum Specific Gravity
1.09
Cord
6 ft.
Metered
No
Drain Plug
No
Mfr. Part Number
33101
Duty
Intermittent
Mfr. Warranty Length
2 yr.
Duty Cycle
Intermittent
Motor Enclosure
IP55
Food Grade
No
Motor RPM
1,750 RPM
Full Load Amps
4-1/2
Motor Type
2 Pole
GPM
8
Outlet
3/4"
GPM of Water @ 1 Ft. of Head
8
Package Quantity
1
GPM of Water @ 10 Ft. of Head
8
Phase
1
GPM of Water @ 15 Ft. of Head
8
Port Rotation
No
GPM of Water @ 20 Ft. of Head
7
Power Source
Electric
GPM of Water @ 25 Ft. of Head
6
RPM
1730
GPM of Water @ 30 Ft. of Head
5
Screw Material
Stainless Steel
GPM of Water @ 35 Ft. of Head
4
Seal Application
Nonflammable and Nonabrasive Liquids Compatible with Seal Component Materials
GPM of Water @ 40 Ft. of Head
3
Seal Material
EPDM
GPM of Water @ 5 Ft. of Head
2
Seal Type
Mechanical
GPM of Water @ 50 Ft. of Head
1
Self-Priming
Yes
Height
6-47/64 in.
Service Factor
1
Horsepower
1/10
Shaft Material
Stainless Steel
Housing Material
Plastic
Shipping Weight
14.6 lb.
Hz
60
Suction Lift
6 ft.
Impeller Type
Nutating Diaphragm
Variable Speed
No
Inlet
3/4"
Voltage
115
Item
Electric Operated Drum Pump
Wetted Materials
EPDM, Polypropylene, Stainless Steel
Length
11-11/32 in.
Width
7 in.
Maximum Case Pressure
40 psi
General
Application
Diesel Exhaust Fluid, Anti-Freeze, Clean Water
Max. Fluid Temp.
104 Degrees F
Compatible Chemicals
Acetic Acid 20%, Ammonium Hydroxide, Antifreeze (Coolant), Citric Acid 50%, DEF, Deionized Water, Ethyl (Ethanol), Ethylene Glycol, Formaldehyde, Formaldehyde 40%, Fresh Water, Glycerin, Isopropyl (Isopropanol), Potassium Hydroxide (50%), Salt Water, Sodium Bicarbonate (10%), Sodium Bisulfite, Sodium Hypochlorite/Bleach (to 20%)
Max. Head - Pumps
48 ft
Diesel Exhaust Fluid Compatible
Yes
Max. Head Pressure
23 psi
Discharge Connection Type
Hose Barb
Max. Oil Flow
8 gpm
Discharge Tube Outlet ID
3/4 in
Max. Outlet Pressure
23 psi
Discharge Tube Outlet OD
1 in
Max. Viscosity
10 cps
For Container Size
55 gal, 275 gal, 330 gal
Min. Fluid Temp.
17 Degrees F
For Container Type
Drum, Tote
Noise Level
70 db
For Media Type
Acetic Acid, Ammonium Hydroxide, Antifreeze, Bleach, Citric Acid, DEF, Ethanol, Ethylene Glycol, Formaldehyde, Glycerin, Isopropanol, Potassium Hydroxide (50%), Sodium Bicarbonate, Sodium Bisulfite, Water
Nominal Voltage
110V AC
For Use With
Anti-Freeze, Clean Water, Diesel Exhaust Fluid
Not Recommended Chemicals
Acetic Acid (Glacial), Acetic Acid 80%, Acetone, Ammonia (Liquids), Anhydrous Ammonia, Automatic Transmission Fluid, Biodiesel, Brake Fluid, Calcium Chloride, Chromic Acid 10%, Chromic Acid 30%, Chromic Acid 5%, Chromic Acid 50%, Cyclohexane, Diesel Fuel, E85, Ethyl Acetate, Fertilizers, Formic Acid, Fungicides, Gasoline, Heptane, Herbicides, Hexane, Hydraulic Oils (Petroleum), Hydraulic Oils (Synthetic), Hydrazine, Hydrochloric/Muriatic Acid (100%), Hydrochloric/Muriatic Acid (20%), Hydrochloric/Muriatic Acid (37%), Hydrofluoric Acid (20%), Hydrofluoric Acid (75%), Hydrofluoric Acid 100%, Kerosene, Lacquer Thinners, Lithium Grease, Methyl (Methanol), Methyl Chloride, Methyl Ethyl Ketone (MEK), Motor Oil, Naphtha, Nitric Acid (10% Solution), Nitric Acid (20% Solution), Nitric Acid (50% Solution), Nitric Acid (Concentrated Solution), Paint, Paint Thinner, Pesticides, Phosphoric Acid (40% Solution), Sodium Bisulfate, Sodium Hydroxide/Caustic Soda (20%), Sodium Hydroxide/Caustic Soda (50%), Sodium Hydroxide/Caustic Soda (80%), Stoddard Solvent (Mineral Spirits), Sulfuric Acid (10% - 75%), Sulfuric Acid (75% - 100%), Sulfuric Acid (to 10%), Toluene, Trichlorethylene (50%), Turpentine, Windshield Washer Fluid, Xylene
Frequency (Hz)
60
Number of Phases
1
Housing Material - Pumps
Polypropylene
Pump Package Type
Basic Pump without Discharge Hose
Includes Suction Tube
Yes
Rated Voltage
115V AC
Max. Flow Rate
8 gpm
Runs Dry
Yes

Product Description

Diesel exhaust fluid (DEF) stationary electric drum pumps are used specifically with DEF to maintain purity when filling the reservoir of a diesel engine's Selective Catalytic Reduction (SCR) system. These pumps are certified to ISO standards that regulate the handling, transportation, and storage of DEF. They are used for dispensing and transferring moderate to large volumes of DEF when servicing late model trucks and SUVs as well as SCR-based stationary industrial systems that operate on diesel fuel.

Item Barcode
9193920
Self-Priming Pump,1/10 Hp,1
 NameItemDescription
Grainger DropshipGrainger Dropship45NC04Self-Priming Pump,1/10 HP,
UNSPSC CODESUNSPSC CODES40151503
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009Self-Priming Pump,1/10 HP,

For more product information by email, click here