Share  
Print  
BUSSMANN

Bussmann 2A Time Delay Melamine Fuse with 600VAC/300VDC Voltage Rating; LP-CC Series

Hover over image to magnify
Fuse,2A,Class CC,Lpcc,600VAC/
PI_Asset_3731673
PI_Asset_3731674
Fuse,2A,Class CC,Lpcc,600VAC/
PI_Asset_3731673
PI_Asset_3731674

#918473-1 | Pkg Qty: 1

$39.05 pkg | $39.05 ea

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
In Line Fuseholder
D/W
Amperage
2 A
Indicating / Nonindicating
Nonindicating
Body Material
Melamine
Interrupt Rating
200kA at 600VAC, 20kA at 300VDC
Body Style
Cylindrical
Item
Fuse
Brand
BUSSMANN
Length
1-1/2 in.
Class
CC
Mfr. Part Number
LP-CC-2
DC Voltage Rating
300 VDC
Package Quantity
1
Diameter
13/32 in.
Rejection / Nonrejection
Rejection
Element
Dual
Series
Lp-Cc
Functionally Equal To
Mersen/Ferraz Shawmut ATDR, Littelfuse CCMR
Shipping Weight
.01 lb.
Fuse Amps
2A
Speed
Time Delay
Fuse Holder Code
D/W
Type
Low Voltage
Fuse Speed
Time Delay
Voltage Rating
600 VAC/300 VDC
Fuse Voltage Rating
600 VAC/300 VDC
General
Compatible Fuse Block Series
BC, BCM, C2617, C5268, CHCC, HPF, OPM-1038, OPM-NG
Fuse Size
1-1/2 in L x 13/32 in dia
Equivalent Series
ATDR, CCMR, LP-CC
Standards
CE/UL-248-4 Guide JDDZ/CSA Class 1422-02
Fits Fuse Block Style
Rejection
Visual Indication
Nonindicating

Product Description

Time-delay, nonindicating UL Class CC fuses tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class CC fuses, they open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. Series LP-CC, ATDR, and CCMR fuses protect small motors and branch-circuit components. Series FNQ-R, ATQR, and KLDR handle inductive loads from devices such as control transformers and solenoids.

UL Class CC fuses provide a high interrupting rating and current limitation for overcurrent protection of branch circuits, control circuits, lighting, transformers, and general loads. Their rejection feature ensures a match with Class CC rejection fuse blocks and holders that prevent midget fuses from being installed. These 600VAC fuses have an interrupting rating (IR) of 200kA and are the smallest 600VAC, 200kA fuses approved for branch circuits. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Expertly Selected Product Pairings

Puller,Fuse,Small
$28.19 pkg | $28.19 ea
Item: 914681-1 | Pkg Qty: 1
Fuse Holder,Midget,30A,1 Pole
$37.02 pkg | $37.02 ea
Item: 920778 | Pkg Qty: 1
Fuse Block,Class CC,30A,3 Pole
$248.25 pkg | $248.25 ea
Item: 930017-1 | Pkg Qty: 1

Item Barcode
9184731
Fuse,2A,Class CC,Lpcc,600VAC/
 NameItemDescription
Grainger DropshipGrainger Dropship1CX49Fuse,2A, Class CC,
UNSPSC CODESUNSPSC CODES39121609
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009Fuse,2A, Class CC,

For more product information by email, click here