Share  
Print  
DAYTON

Dayton Line Volt Mechanical Tstat for Heating/Cooling, 24 to 600VAC

Hover over image to magnify
Line Voltage T-Stat,0 To 120 F,
PI_Asset_1370870
Line Voltage T-Stat,0 To 120 F,
PI_Asset_1370870

#914383-9 | Pkg Qty: 1

$85.25 pkg | $85.25 ea

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
Agency Compliance
UL, CUL
Mounting Position
Vertical or Horizontal
Brand
DAYTON
Number of Stages
1
Color Family
Beige
Package Quantity
1
Depth
2-1/2 in.
Shipping Weight
.9 lb.
Differential
3.5°F
Switch Type
SPDT
Height
4-1/2 in.
Voltage
24 to 600 VAC
Item
Line Voltage Mechanical Thermostat
Width
2-1/2 in.
Mfr. Part Number
2NNR6
General
Bulb Length
5 in
Locked Rotor Amps @ 240V
48 A
Capillary Length
60 in
Maximum Control Temperature
120 Degrees F
Capillary Length/Bulb Diameter
5 ft Capillary, 5 in x 1/4 in Bulb
Minimum Control Temperature
0 Degrees F
Changeover Type
Automatic
Number of Cooling Stages
1
Compatible System Type
Attic Fans, Fan Coil Units
Number of Heating Stages
1
Contact Rating Resistive @ 120V
22 A
Number of Switches
1
Contact Rating Resistive @ 240V
22 A
Pilot Duty Rating
125 VA @ 24 to 600V AC
Contact Rating Resistive @ 277V
22 A
Resistive Amps @ 208V AC
22 A
Contact Type
Snap Action
Sensor Location
Remote
Differential Type
Fixed
Sensor Type
Hydraulic Capillary Bulb (Copper)
Electrical Connection Type
Hardwired
Switch Action
Open/Close on Rise
Enclosure Material
Plastic
Switch Type/Action
SPDT, Open/Close on Rise
Enclosure NEMA Rating
NEMA 4X
Temperature Control Range
0 Degrees to 120 Degrees F
For Use With
Motor Driven Ventilator
Temperature Differential
3 Degrees F
Includes
Mounting Hardware
Temperature Scale
Fahrenheit
Inductive Amps @ 120V
16 A
Temperature Sensitivity
+/-3 Degrees F
Inductive Amps @ 208V
9.2 A
Thermostat Type
Indoor Single-Stage Controls
Locked Rotor Amps @ 120V
96 A

Product Description

These temperature controls are suitable for indoor heating, cooling, and refrigeration applications. They have enclosures that meet NEMA 1 for use indoors. These controls can be used with optional, closed tank fittings and immersion wells for immersion applications. These controls are compatible with single-stage systems. Single-stage systems have a single output level and allow the system to be either on or off. These temperature controls have a capillary tube and sensor that monitor and regulate the temperature of the ambient air, a liquid, or a gas at a distance away from the control. The sensing element is not affected by changes in barometric pressure or cross-ambient conditions to ensure accurate temperature regulation.

Item Barcode
9143839
Line Voltage T-Stat,0 To 120 F,
 NameItemDescription
Grainger DropshipGrainger Dropship2NNR6Line Voltage T-Stat,0 to
UNSPSC CODESUNSPSC CODES41112209
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009Line Voltage T-Stat,0 to

For more product information by email, click here