Bussmann 30A Time Delay Melamine Fuse with 600VAC/300VDC Voltage Rating; LPS-RK-SP Series

Hover over image to magnify
Fuse,RK1,Lps-Rk-Sp,30A,600VAC/
Fuse,RK1,Lps-Rk-Sp,30A,600VAC/

#913120-2 | Pkg Qty: 1

$51.66 pkg | $51.66 ea

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
Indicating / Nonindicating
Nonindicating
Amperage
30 A
Interrupt Rating
300kA at 600VAC, 100kA at 300VDC
Body Material
Melamine
Item
Fuse
Body Style
Cylindrical
Length
5 in.
Brand
BUSSMANN
Mfr. Part Number
LPS-RK-30SP
Class
RK1
Package Quantity
1
DC Voltage Rating
300 VDC
Rejection / Nonrejection
Rejection
Diameter
13/16 in.
Series
Lps-Rk-Sp
Element
Dual
Shipping Weight
.16 lb.
Functionally Equal To
Mersen/Ferraz Shawmut A6D-R, Littelfuse LLSRK
Speed
Time Delay
Fuse Amps
30A
Type
Low Voltage
Fuse Holder Code
P
Voltage Rating
600 VAC/300 VDC
Fuse Speed
Time Delay
Width
13/16 in.
Fuse Voltage Rating
600 VAC/300 VDC
General
Compatible Fuse Block Series
1BR, R600
Fuse Size
5 in L x 13/16 in dia
Equivalent Series
A6D-R, LLSRK, LPS-RK-SP
Standards
CE, UL Special Purpose Guide JFHR, Guide JDDZ, File E4273, CSA Class 1422-02, File 53787, CSA C22.2, No. 248.12
Fits Fuse Block Style
Rejection
Visual Indication
Nonindicating

Product Description

Time-delay, nonindicating UL Class RK1 fuses tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK1 fuses, they open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK1 fuses are more current-limiting than RK5 fuses to react more quickly to overcurrent. These fuses are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. These fuses are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Expertly Selected Product Pairings

Puller,Fuse,Medium
$46.05 pkg | $46.05 ea
Item: 915926-8 | Pkg Qty: 1

Item Barcode
9131202
Fuse,RK1,Lps-Rk-Sp,30A,600VAC/
 NameItemDescription
Grainger DropshipGrainger Dropship4XF75Fuse,RK1,LPS- RK-SP,30A,
UNSPSC CODESUNSPSC CODES39121604
VMRS (ATA) CODESVMRS (ATA) CODES034-004-009Fuse,RK1,LPS- RK-SP,30A,

For more product information by email, click here