Share  
Print  
BUSSMANN

Bussmann 225A Time Delay Melamine Fuse with 600VAC/300VDC Voltage Rating; LPS-RK-SP Series

Hover over image to magnify
Fuse,RK1,Lps-Rk-Sp,225A,600VAC/
Fuse,RK1,Lps-Rk-Sp,225A,600VAC/

#913117-5 | Pkg Qty: 1

$704.50 pkg | $704.50 ea

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
Fuse Voltage Rating
600 VAC/300 VDC
Amperage
225 A
Indicating / Nonindicating
Nonindicating
Body Material
Melamine
Interrupt Rating
100k A at 300 VDC, 300k A at 600 VAC
Body Style
Blade
Item
Fuse
Brand
BUSSMANN
Length
11-5/8 in.
Class
RK1
Mfr. Part Number
LPS-RK-225SP
DC Voltage Rating
300 VDC
Package Quantity
1
Diameter
2-3/8 in.
Rejection / Nonrejection
Rejection
Element
Dual
Series
Lps-Rk-Sp
Functionally Equal To
Mersen/Ferraz Shawmut A6D-R, Littelfuse LLSRK
Shipping Weight
2.35 lb.
Fuse Amps
225A
Speed
Time Delay
Fuse Holder Code
T
Type
Low Voltage
Fuse Speed
Time Delay
Voltage Rating
600 VAC/300 VDC
General
Compatible Fuse Block Series
1BR, R600
Fuse Size
11-5/8 in L x 2-3/8 in dia
Equivalent Series
A6D-R, LLSRK, LPS-RK-SP
Standards
CE, UL Special Purpose Guide JFHR, Guide JDDZ, File E4273, CSA Class 1422-02, File 53787, CSA C22.2, No. 248.12
Fits Fuse Block Style
Rejection
Visual Indication
Nonindicating

Product Description

Time-delay, nonindicating UL Class RK1 fuses tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK1 fuses, they open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK1 fuses are more current-limiting than RK5 fuses to react more quickly to overcurrent. These fuses are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. These fuses are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Item Barcode
9131175
Fuse,RK1,Lps-Rk-Sp,225A,600VAC/
 NameItemDescription
Grainger DropshipGrainger Dropship6F330Fuse,RK1,LPS- RK-SP,225A,
UNSPSC CODESUNSPSC CODES39121604
VMRS (ATA) CODESVMRS (ATA) CODES034-004-009Fuse,RK1,LPS- RK-SP,225A,

For more product information by email, click here