Share  
Print  
BUSSMANN

Bussmann Fuse: 30 A, 600V AC, 5 in L x 13/16 in dia Fuse Size, Cylindrical Body, FRS-R

Hover over image to magnify
Frs-R-30 30 Amp Fuse
Frs-R-30 30 Amp Fuse

#912643-1 | Pkg Qty: 1

$28.23 pkg | $28.23 ea
Fuse Amps : 30A

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
Indicating / Nonindicating
Nonindicating
Body Material
Fiberglass
Interrupt Rating
200kA at 600 VAC, 20kA at 300 VDC
Body Style
Cylindrical
Item
Fuse
Brand
BUSSMANN
Length
5 in.
Class
RK5
Mfr. Part Number
FRS-R-30
DC Voltage Rating
300 VDC
Pack Quantity
1
Diameter
13/16 in.
Rejection / Nonrejection
Rejection
Element
Dual
Series
FRS-R
Functionally Equal To
Littelfuse FLSR, Mersen/Ferraz Shawmut TRS-R
Shipping Weight
.16 lb.
Fuse Amps
30A
Speed
Time Delay
General
Compatible Fuse Block Series
1BR, R600
Fuse Size
5 in L x 13/16 in dia
Equivalent Series
ECSR, FLSR, FRS-R, TRS-R
Standards
CE, CSA Certification Class 1422-01, UL 248-12 Guide JDDZ

Product Description

These 600VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK5 fuses provide moderate current limitation for general use applications where more current-limiting RK1 fuses aren't needed. These fuses have an interrupting rating (IR) of 200kA and are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Expertly Selected Product Pairings

Puller,Fuse,Small
$28.19 pkg | $28.19 ea
Item: 914681-1 | Pkg Qty: 1
Fuse Reducer,H, K,30 A,Holder
$32.46 pkg | $32.46 ea
Item: 931948-6 | Pkg Qty: 1

Item Barcode
9126431
Frs-R-30 30 Amp Fuse
 NameItemDescription
Grainger DropshipGrainger Dropship1A706Fuse,RK5,FRS- R,30A,600VAC/
UNSPSC CODESUNSPSC CODES39121604
VMRS (ATA) CODESVMRS (ATA) CODES034-004-009Fuse,RK5,FRS- R,30A,600VAC/

For more product information by email, click here