Share
Print
BELL & GOSSETT
Hydronic Circulating Pump: Standard, Bell & Gossett, Flanged, 1/12 HP, 25 ft Max. Head
Hover over image to magnify
#912261-8Pkg Qty: 1
$762.74 pkg | $762.74 ea
In Stock
Shipping to 43085
Expected to arrive Fri. Apr 04.
Technical Specifications
Key Specifications
Amps
1.4
Item
Hydronic Circulating Pump
Bearing Type
Ball
Length
8-5/8 in.
Best Efficiency GPM @ Head
15 gpm @ 13 ft.
Loop Configuration
Closed
Brand
BELL & GOSSETT
Maximum GPM @ Head
30 gpm @ 1 ft.
Connection Style
Flange
Maximum Head
24 ft.
Drive Type
Direct
Maximum Operating Pressure
150 psi
Face to Face Dimension
6-3/8 in.
Maximum Temperature (Deg. F)
225
Flange/Union Included
No
Maximum Working Pressure
150
GPM of Water @ 1 Ft. of Head
30
Mechanical Seal
Maintenance Free
GPM of Water @ 10 Ft. of Head
21
Mfr. Part Number
1BL012
GPM of Water @ 11 Ft. of Head
18
Mfr. Warranty Length
1 yr.
GPM of Water @ 12 Ft. of Head
17
Minimum GPM @ Head
7 gpm @ 20 ft.
GPM of Water @ 15 Ft. of Head
13
Package Quantity
1
GPM of Water @ 2 Ft. of Head
27
Phase
1
GPM of Water @ 20 Ft. of Head
7
Pump Mount
Nonmetallic
GPM of Water @ 3 Ft. of Head
27
Pump Type
Maintenance Free
GPM of Water @ 4 Ft. of Head
26
RPM
2650 RPM
GPM of Water @ 5 Ft. of Head
26
Series
Pl
GPM of Water @ 6 Ft. of Head
24
Shaft Material
Carbon/Silicon Carbide
GPM of Water @ 7 Ft. of Head
23
Shipping Weight
12.65 lb.
GPM of Water @ 8 Ft. of Head
22
Shut-Off
24 ft.
GPM of Water @ 9 Ft. of Head
22
Speed
1
HVAC Circulating Pump Type
Hydronic Circulating Pump
Style
Maintenance-Free
Horsepower
1/12
Thermal Protection
Auto
Housing Material
Cast Iron
Type
Closed Loop
Impeller Material
Steel
Voltage
115 VAC
Inlet/Outlet
Flanged
Width
4-3/8 in.
Inlet/Outlet Size
3/4 in. to 1-1/2 in.
General
Brand and Connection Combo
BELL & GOSSETT , Flange Connection
Maximum Flow Rate @ 25 Feet of Head
0 gpm
Compatible Intake Pipe Size
3/4 in, 1 in, 1 1/4 in, 1 1/2 in
Maximum Flow Rate @ 5 Feet of Head
25 gpm
For Use With Potable Systems
Yes
Motor Enclosure Design
Totally Enclosed Fan-Cooled
GPM of Water @ 18 Ft. of Head
9
Mounting Location
In-Line
Maximum Feet of Head
25 ft
Nameplate Voltage
115V AC
Maximum Flow Rate @ 10 Feet of Head
20 gpm
Phase and Brand
BELL & GOSSETT Single Phase
Maximum Flow Rate @ 15 Feet of Head
15 gpm
Product Description
Hot Water Circulating Pumps
- 1-phase models are thermally protected Cast-iron units are not for potable water Maintenance-Free, PL Series
- Max. working pressure: 150 psi Max. temp.: 225°F Close-coupled dry-motor design with permanently lubricated X-11 precision-crafted bearing system and nonmetallic impellers. Provide dependable seasonal startups, long life, and quiet operation.
Expertly Selected Product Pairings






Others also viewed
Item Barcode
Pump,Circulator,1/12hp