Bussmann 20A Fast Acting Melamine Fuse with 600VAC Voltage Rating; KTK-R Series

Hover over image to magnify
Fuse,Ktk-R,20A,600V,13/32 Dia,
Fuse,Ktk-R,20A,600V,13/32 Dia,

#911898-7 | Pkg Qty: 1

$34.35 pkg | $34.35 ea

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
In Line Fuseholder
D/W
Amperage
20 A
Indicating
No
Body Material
Melamine
Indicating / Nonindicating
Nonindicating
Body Style
Cylindrical
Interrupt Rating
200kA at 600VAC
Brand
BUSSMANN
Item
Fuse
Class
CC
Length
1-1/2 in.
DC Voltage Rating
Not Rated
Mfr. Part Number
KTK-R-20
Diameter
13/32 in.
Package Quantity
1
Element
Single
Rejection / Nonrejection
Rejection
Functionally Equal To
Mersen/Ferraz Shawmut ATMR, Littelfuse KLKR
Series
Ktk-R
Fuse Amps
20A
Shipping Weight
.01 lb.
Fuse Holder Code
D/W
Speed
Fast Acting
Fuse Speed
Fast Acting
Type
Low Voltage
Fuse Voltage Rating
600 VAC
Voltage Rating
600 VAC
General
Compatible Fuse Block Series
BC, BCM, C2617, C5268, CHCC, HPF, OPM-1038, OPM-NG
Fuse Size
1-1/2 in L x 13/32 in dia
Equivalent Series
ATMR, KLKR, KTK-R
Standards
CE/UL-248-4 Guide JDDZ/CSA Class 1422-02
Fits Fuse Block Style
Rejection
Visual Indication
Nonindicating

Product Description

Fast-acting, nonindicating UL Class CC fuses open within seconds of being exposed to overloads and short circuits. These series KTK-R, KLKR, and ATMR fuses are commonly found in appliances, integrated circuits, control circuits, control circuit transformers, and other equipment with specific current-limitation requirements. Also called fast-blow Class CC fuses, they are highly sensitive to changes in current flow and don't tolerate temporary overload currents or power surges. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class CC fuses provide a high interrupting rating and current limitation for overcurrent protection of branch circuits, control circuits, lighting, transformers, and general loads. Their rejection feature ensures a match with Class CC rejection fuse blocks and holders that prevent midget fuses from being installed. These 600VAC fuses have an interrupting rating (IR) of 200kA and are the smallest 600VAC, 200kA fuses approved for branch circuits. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Expertly Selected Product Pairings

Puller,Fuse,Small
$28.19 pkg | $28.19 ea
Item: 914681-1 | Pkg Qty: 1
Fuse Holder,Midget,30A,1 Pole
$37.02 pkg | $37.02 ea
Item: 920778 | Pkg Qty: 1
Fuse Holder,Midget,30A,1 Pole
$63.15 pkg | $63.15 ea
Item: 925422-7 | Pkg Qty: 1
Fuse Block,Class CC,30A,3 Pole
$248.25 pkg | $248.25 ea
Item: 930017-1 | Pkg Qty: 1

Item Barcode
9118987
Fuse,Ktk-R,20A,600V,13/32 Dia,
 NameItemDescription
Grainger DropshipGrainger Dropship4XC27Fuse,KTK-R, 20A,600V,
UNSPSC CODESUNSPSC CODES39121609
VMRS (ATA) CODESVMRS (ATA) CODES034-004-009Fuse,KTK-R, 20A,600V,

For more product information by email, click here