Share  
Print  
DAYTON

Brass Solenoid Valve Less Coil, 2-Way Valve Design, Normally Closed Valve Configuration

Hover over image to magnify
Solenoid Valve,2 Way,Nc,1 In,
Solenoid Valve,2 Way,Nc,1 In,

#911779-2 | Pkg Qty: 1

$307.37 pkg | $307.37 ea

Drop Ship Item

Shipping to 60045
|

Required Items

Items below are required. They are not included and need to be ordered separately.
Solenoid Valve Coil,208/240VAC,
Pkg Qty: 1
$35.74 pkg
Solenoid Valve Coil,208/240VAC,
Pkg Qty: 1
$35.74 pkg
Solenoid Valve Coil,208/240VAC,
Pkg Qty: 1
$35.74 pkg
Solenoid Valve Coil,24VAC,60/
Pkg Qty: 1
$28.55 pkg
Solenoid Valve Coil,24VAC,60/
Pkg Qty: 1
$28.55 pkg
Solenoid Valve Coil,24VAC,60/
Pkg Qty: 1
$28.55 pkg
Solenoid Valve Coil,208/240VAC,
Pkg Qty: 1
$63.01 pkg
Solenoid Valve Coil,208/240VAC,
Pkg Qty: 1
$63.01 pkg
Solenoid Valve Coil,208/240VAC,
Pkg Qty: 1
$63.01 pkg

Technical Specifications

Key Specifications
Agency Compliance
CSA, NFPA, UL
Mfr. Part Number
8047
Body Material
Brass
Operation Type
Pilot Operated
Brand
DAYTON
Overall Height
5-3/16 in.
Coefficient of Volume
13
Overall Length
4-1/16 in.
Configuration
Normally Closed
Package Quantity
1
Flow Range
29.1 to 205.5 GPM
Pipe Size
1 in.
Item
Solenoid Valve Less Coil
Shipping Weight
1.75 lb.
Maximum Fluid Temperature
180°F
Valve Design
2-Way
Media Type
Air, Steam, Water
orifice Dia._spec_s
1 in.
General
Airflow
286 to 1703 scfm
Media - Valves
Air, Steam, Water
Body Material - Valves
Brass
Min. Operating Pressure Differential
5 psi
Coil Insulation Class
F
Pipe Size - Valves
1 in
Environmental Rating - Valves
Indoor, Outdoor
Safe Working Water Pressure
300 psi
For Use With
Dayton Solenoid Coils
Seal Material - Valves
Buna-N
Max. Operating Pressure Differential Air/Inert Gas
250 psi
Solenoid Valve Product Group
Solenoid Valve Less Coil
Max. Operating Pressure Differential Light Oil
250 psi
Valve Configuration
Normally Closed
Max. Operating Pressure Differential Water
250 psi
Valve Ways and Positions
2-Way

Product Description

Solenoid Valves

  • Mount in any position To prevent backflow, add a check valve to the system (sold separately on page 4059). Valves that have OPD minimums beginning with 0 (e.g., 0 to 300 psi) are direct-acting and will open and close when line pressures are within minimum and maximum psi ranges. Valves that have OPD minimums starting at 2 or 5 (e.g., 5 to 150 psi) are designated pilot-operated and will open and close only if pressure differential between the inlet and outlet is within OPD ranges. Normally closed valves will open when energized. Normally open valves will close when energized. Standards: UL; CSA; Fluid Control Institute, Inc.; National Fluid Power Association (NFPA). WARNING: Not for use in explosive atmospheres. Note: Maximum suggested cycling rate is 10 times per min.

Expertly Selected Product Pairings

Solenoid Valve Coil,120VAC,60/
$28.95 pkg | $28.95 ea
Item: 913788-9 | Pkg Qty: 1
Solenoid Valve Coil,24VAC,60/
$60.66 pkg | $60.66 ea
Item: 915825-9 | Pkg Qty: 1
Solenoid Valve Coil,120VAC,60/
$68.39 pkg | $68.39 ea
Item: 915887 | Pkg Qty: 1
Solenoid Valve Coil,120VAC,60/
$33.41 pkg | $33.41 ea
Item: 924275-9 | Pkg Qty: 1
Solenoid Valve Coil,120VAC,60/
$148.73 pkg | $148.73 ea
Item: 926296-8 | Pkg Qty: 1
Solenoid Valve Coil,24VAC,60/
$85.29 pkg | $85.29 ea
Item: 926936-3 | Pkg Qty: 1
Valve Rebuild Kit,With
$128.97 pkg | $128.97 ea
Item: 935116-1 | Pkg Qty: 1

Compliance & Restrictions

California Proposition 65 Icon
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
Item Barcode
9117792
Solenoid Valve,2 Way,Nc,1 In,
 NameItemDescription
Grainger DropshipGrainger Dropship3A438Solenoid Valve,2 Way,
UNSPSC CODESUNSPSC CODES40141605
VMRS (ATA) CODESVMRS (ATA) CODES053-008-006Solenoid Valve,2 Way,

For more product information by email, click here