Share  
Print  
BUSSMANN

Bussmann Fuse: 60 A, 600V AC, 5-1/2 in L x 1-1/16 in dia Fuse Size, Cylindrical Body, FRS-R

Hover over image to magnify
Fuse,Frs-R,60A,600V,1 1/6 Dia,
Fuse,Frs-R,60A,600V,1 1/6 Dia,

#911610-2 | Pkg Qty: 1

$52.51 pkg | $52.51 ea
Fuse Amps : 60A

Drop Ship Item

Shipping to 60045
|

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
Indicating / Nonindicating
Nonindicating
Body Material
Fiberglass
Interrupt Rating
200kA at 600 VAC, 20kA at 250 VDC
Body Style
Cylindrical
Item
Fuse
Brand
BUSSMANN
Length
5-1/2 in.
Class
RK5
Mfr. Part Number
FRS-R-60
DC Voltage Rating
250 VDC
Package Quantity
1
Diameter
1-1/16 in.
Rejection / Nonrejection
Rejection
Element
Dual
Series
FRS-R
Functionally Equal To
Littelfuse FLSR, Mersen/Ferraz Shawmut TRS-R
Shipping Weight
.3 lb.
Fuse Amps
60A
Speed
Time Delay
General
Compatible Fuse Block Series
1BR, R600
Fuse Size
5-1/2 in L x 1-1/16 in dia
Equivalent Series
ECSR, FLSR, FRS-R, TRS-R
Standards
CE, CSA Certification Class 1422-01, UL 248-12 Guide JDDZ

Product Description

These 600VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK5 fuses provide moderate current limitation for general use applications where more current-limiting RK1 fuses aren't needed. These fuses have an interrupting rating (IR) of 200kA and are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Expertly Selected Product Pairings

Puller,Fuse,Medium
$46.05 pkg | $46.05 ea
Item: 915926-8 | Pkg Qty: 1
Fuse Block,60A,Box Lug,7.3 In.
$176.37 pkg | $176.37 ea
Item: 927383-8 | Pkg Qty: 1

Item Barcode
9116102
Fuse,Frs-R,60A,600V,1 1/6 Dia,
 NameItemDescription
Grainger DropshipGrainger Dropship1A707Fuse,FRS-R, 60A,600V,1
UNSPSC CODESUNSPSC CODES39121604
VMRS (ATA) CODESVMRS (ATA) CODES034-004-009Fuse,FRS-R, 60A,600V,1

For more product information by email, click here